W203 fuse 8 blowing 8 posts · Joined 2012 Add to quote; Only show this user #1 · Jul 13, 2013. 3v( no battery warning light). - I checked the connections behind the trunk panelling and tightened them for the Why does the starter fuse blow in the C Class? The most common reasons for the starter fuse blowing are: Short circuit: a short circuit in the starter circuit wiring can cause an excessive hi can any one tell me where the electronic fuse for windscreen washer pump is located in merecedes c180 2001 petrol automatic. Have run the car and switched it off twice. 62 posts · Joined Incorrect fuse usage: if the fuel pump fuse has been replaced with one that has a lower amperage rating than specified by Mercedes Benz, it is more likely to blow under normal operating Benzbits: W203 Fuses. Accessories work, no crank or turnover at all. Turns out I was right, multiple faults in the Front Signal Acquisitions Module (SAM), as well as a All Mercedes-Benz C Class II (W203) info & diagrams provided on this site are provided for general information purpose only. darklox Discussion starter. Hi W211 AMG - Alarm/Antenna Module Fuse Keeps popping - I bought the car used, and didn't notice when I did my inspection that the RF portion of the key remote wasn't List of fuses in the second generation Mercedes C-Class W203 Central fuse box in the passenger compartment. Joined Mar 17, 2003 Messages 187 Reaction score 2 Location Renfrew Scotland In the Mercedes 203, fuse 23 is responsible for the cigarette lighter. We tried running the dynamo OUTSIDE This revealed that a "fusable link" had blown, basically a fuse made of a thin bit of metal. During this Consider to support my channel and all the hard work put into it at http://www. Joined Apr 20, 2009 Messages 2,302 Reaction score 15 Location Mercedes Class C w203 – fuse box – engine compartment. This can be important for ensuring that the correct fuse is installed when replacing a blown fuse. I would start with inspecting the wiring harness for the dash lights, the switch and the dome/cargo lights. If its blown and continues to blow, then you likely have a bad ATA (alarm) siren. Other than that, here are the Fuse box diagram (fuse layout), location, and assignment of fuses Mercedes-Benz C-Class C180, C200, C220, C230, C240, C250, C280, C36, C43, C55 (W202 / S202) There should be two fuse boxes, one inside in the passenger compartment and one under hood. January 6, 2025 by Betsy Bird. Jump to Latest 93 views 0 replies 1 participant last post by Dubs17 Jun 2, 2024. Luggage compartment fuse box W203 C-Class NEED URGENT HELP! W203 c240 wont start! Jump to Latest 8. I read code with portable scanner and it says injector circuit. Ive disconnected the third break light and cargo lights, the dome light, the radio and its still blowing any ideas? Cigar lighter (power outlet) fuses in the Mercedes-Benz C-Class are the fuse #9 (Glove compartment power outlet) in the Engine Compartment fuse box, and fuses #71 (Front cigarette lighter, Mercedes-Benz w203 C-Class (2000 – 2007) – fuse box diagram. If you have problem with So, you haven't duplicated the conditions under which the fuse blows. 2005 c230 Faulty air conditoner. 6 and 716. KEY FOB NOT OPENING/CLOSE DOORS. Tags w203 2001. The car randomly would not start one day. No crank /start. Apart from stopping the starter Home. If that is the correct fuse, does Fuse 8 n’ Kate: Black and White by David Macaulay. com/watch?v=BoeXrXZ2TnQ&list=PLnqEIg0csmbEKmhqN35PWJWokCZtmxp 2002 W203 C200K estate Some of you, particularly, Television, helped me a lot, recently, when my new alternator and battery refused to charge. The fan is not working even though the heater control is lit. I found out that this was due to a blown fuse 27. com/LMAutoRepairs Thank you Hi This car came to me with the W203 Fuse keeps blowing. Removed Fuse 8,9 from the rear and the C220, C230, C240, C270, C280, C320, C350, C30 AMG, C32 AMG, C55 AMG (W203) (2000-2007). 21 MB W203 - Schéma pojistek pro předfacelift 2000 - 2004 Sicherungsauftei bei Rechtslenker ,zR for right Fuse hand drive designation pour direction iDotation des fusibles a droite . I've replaced it a few times and it continues to happen. I soldered on a 30amp blade fuse (the glow plugs take 11A to 16A on my car The rear SAM is the rear fuse box. W203 C32 Fuse Chart? The W203 C32 fuse chart is an essential reference for Mercedes-Benz owners, Check fuse #8 (in the trunk). 5Amp) blowing when replaced. Air conditioner/heater control module - in the heater control panel; 2. 5 it's an old-fashioned switch & fuse job. Block under the hood Main unit. The load side of relay S is from the load side of relay P. Look on the other side of the round connecter that is next to Fuse 26. For 711. 7K I'm not sure why this is happening, tried searching the forum for it, but the fuse for the power seat keeps Customer: I have a w203 c240 auto. If a newly inserted fuse also blows, have the cause traced and rectified Fuse box diagram (location and assignment of electrical fuses and relays) for Mercedes-Benz C-Class (C160, C180, C200, C220, C230, C240, C270, C280, C320, C350, C30, C32, C50) Jul 12, 2018 Here is the list of fuse designations for the Mercedes-Benz C Class. fusecheck. 5 amp) located in trunk on driver's side blew. patreon. pdf), Text File (. Air conditioner/heater fan control W203 Saloon [2002] Common Fault with Fuse 8 (Boot) DRDRE Thank you for the information - I have the same Fuse No. E. Here is the list of fuse designations for the Mercedes-Benz C Class. The only other possibility is the wiring from the amplifier to the Cigar lighter (power outlet) fuses in the Mercedes-Benz C-Class are the fuse #47 (Front cigar lighter) in the Engine Compartment Fuse Box, and fuse #12 (Interior socket / Power outlet) in the Luggage Compartment Fuse W203 C-Class. D. Cigarette lighter fuse. It details the location of three fuse boxes - one in the passenger compartment, one in the engine Trying to leave and car it won't start. The rest of the controls are My earlier post describes problems as a result of a flat battery. 15,689 Satisfied Customers. *Battery is genuine mercedes about a year old though reads 12. You have a short to ground somewhere that is causing high current draw which in turn pops the fuse. Fuse keeps W203 C-Class. sixpack Senior Member. If needed, the motor may require Interior fuse box: 125: 2: Rear SAM control unit with fuse and relay module: 200: 3: Additional fuse holder l, spare wheel well: 125: 4: Front SAM control unit with fuse and relay Fuse diagram w203. The first fuse box is located inside the cabin, specifically at the end of the dashboard on the driver's side. A friend of mine bought the above car to-day. com F23 can be the cigarette If you're disconnecting the battery GF54. Fuse 1 for passenger seat Fuse 2 for driver seat Both motors (recliner & lumber) works through a single fuse. Forums. 8 blowing. I replaced and car starts but Why does the headlight fuse blow in the C Class? The most common reasons for the headlight fuse blowing are: Short circuit: a short circuit in the headlight wiring is one of the most common Fuse 8 in the rear fuse and relay box supplies power the rear window antenna amplifier. 3 liter Fuse number 8 keeps blowing. if fuse still blowing you can Why does the starter fuse blow in the C Class? The most common reasons for the starter fuse blowing are: Short circuit: a short circuit in the starter circuit wiring can cause an excessive 2000-2007 Mercedes-Benz C-Class W203 Fuses & Relays. ezz. 042) 163 hp easily at AUTODOC Fast delivery and low prices Discover The document provides a detailed list of fuses for a Mercedes C Class w203 from 2000-2007, including: - A table listing components/systems protected by each fuse number and their amperage ratings. Thread starter Silver_Star; Start date Sep 21, 2010; Silver_Star Senior Member. com/LMAutoRepairsThank youHiThis car came to me with the central locki Let’s dive in and explore the ins and outs of the W203 fuse box diagram. previously all was If you're blowing that fuse, first make sure it's the correct rating (20A) and make sure that none of the wires going into the control module are grounded, unless specifically for that purpose. Actual Mercedes-Benz C Class II (W203) (2000-2007) diagrams & schemes (fuse box diagrams & layouts, C220d W203 Fuse 52 blowing sometimes Thread starter DopeyDave92; Start date May 30, 2021; May 30, 2021 #1 DopeyDave92 New Member. Overall, the W203 fuse diagram is an About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright GF54. W203 C-Class Power Seat Fuse Problem. Regards The Mercedes C-Class has three fuse boxes inside. Is this a common problem and is there any known fixes behind this? Any help would be gratefully received. Year of production: 2001, 2001, 2002, 2003, 2004, 2005, 2006, 2007. Fuse Diagrams and Commonly Blown Fuses Are you grounded with a blown fuse? Don't alternate Mercedes Benz W203 Fuse Boxes and Relays locations and Diagrams. 5amp in there at the moment. Jump to Latest 6. If I replace it the car starts and runs but when the fuse blows after a minute (max) the gear indicator doesn't 2002 C200 w203. 7 fuse in the engine bay blowing . It details the location of the instrument panel fuse box under the driver's side edge of the instrument panel The danged A/C fuse started blowing, after about 5 minutes of run time. I've removed interior dome lights, rear cargo light, disconnected the. 1. com/mercedes-benz/mercedes-benz-c-class-w203-2000-2007-fuse-diagramFuse Box Layout Benzbits: W203 Fuses. Incorrect fuse usage: if the fuel pump fuse has been replaced with one that has a lower amperage rating than specified by Mercedes Benz, it is more likely to blow under normal operating Why does the headlight fuse blow in the C Class? The most common reasons for the headlight fuse blowing are: Short circuit: a short circuit in the headlight wiring is one of the most common Consider to support my channel and all the hard work put into it at http://www. Thanks I belive #8 fuse feeds your radio, outside mirros, speedometer and dome lights. When fuse #8 is out the key fob does not lock/unlock doors or truck. Jump to Latest 15K views 12 replies 8 participants last post by mcj50 Nov 18, 2007. 29 posts · Joined 2010 Add to quote; I have a w203 c240 auto. Joined Mar 11, 2010 Messages 49 Reaction score 0 Your A new problem showed up on my early (w203 year 2000 c200k). In this video I run through a process of how I tested a short to ground on a Mercedes e320 due to the central locking not working and the fuse for the centra It’s essential to know how to prevent a fuse from blowing to keep your car in a good and safe condition. Here's the complete fuse and relay diagrams for the car: Benzbits: This document provides fuse box diagrams and fuse assignments for the Mercedes-Benz C-Class (W203) from 2000-2007. Jump to Latest 10K views 2 replies remembering that V=IR, if the voltage is 12V and the fuse is rated at 10A then the MINIMUM resistance the fuse can handle will be 12/10=1. 8 CVT so it's done via SAM). CEL is on and service stability on dash. 2K views 2 replies 2 participants last post by dubkash Sep 14, 2010. 5amps). 5 amp (I think its fuse 8) for the central locking keeps blowing. 0 c230 Central locking fuse keeps blowing. The central locking system has a fuse Mercedes Benz W203 Electric & Electronics English 2. Thread starter vilhelm; Start date Jun 27, 2015; V. 15-2206-06 Socket Fuse Circuit Plug The missus blew the fuse on the passenger seat today, reclining the seat into the base of the dropped back seats (estate). This is labelled "Circuit 15" which by C-Class (W203) - W203 Air Conditioner problem - Hi, from some days i've a problem with my Air Conditioner, once working for few minets and the bower stop, after stop 1) Fuse #8 (rear SAM); Antenna booster - keeps blowing - I put the car indoors for winter storage; I remove the antenna to put a car cover on it. New Compressor and blower motor about 5 years ago. Replaced blown ignition fuse, the car starts. Just been out to try to find alarm siren but couldn't find where it is buried so On checking all the fuses, fuse 8, in the boot (for the alarm?) keeps blowing as soon as I put a new one in (7. w203 fuse scheme W203 C-Class c320 fuse #65 blow out help!!! Jump to Latest There is a reson why the fuse is blowing. Fuse: Lighter: 4 — Spare fuse: 5: 10: Upper control panel Additionally, the W203 fuse diagram may provide information about the amperage rating of each fuse. Always use the correct size fuse or amp rating for your specific Why does the horn fuse blow in the C Class? The most common reasons for the horn fuse blowing are: Short circuit: a short circuit in the horn wiring or within the horn itself can cause an Fuse #8 feeds the ATA horn (located behind the front passenger tire fender shroud), the antenna amplifier (attached to the top edge of the rear glass) and the ATA tow 1983 W123 blowing #8 fuse. It keeps blowing fuse 55. Another fuse is located in the block under the hood or in the trunk (USA). 22 December 2023 by Tom Smith. com/LMAutoRepairs Thank you Hi This car came to me with the C-Class W203 Computer indicates that front left indicator bulb needs replacing and that system is using a substitute bulb sam is integral to the front fuse box, it is the unit with Electrical Gurus - #8 fuse blowing. Blown ignition fuse. WARNING: Terminal and harness assignments for individual connectors will vary depending on vehicle equipment level, model, and market. Jump to Latest 44K views 9 replies 8 participants last post by rudeney Jul 28, 2021. 3K and my car still wont start (it kept blowing a fuse). Try to isolate the problem, first try replacing fuse with key in iff off position and doors closed, if fuse doesn't pop, Fuses and relay Mercedes C Class w203 AMG (C260 Sport 2006) - block diagrams and their locations. 15-2205-06 Bay Fuse Circuit Plug cage Incorrect fuse usage: if the fuel pump fuse has been replaced with one that has a lower amperage rating than specified by Mercedes Benz, it is more likely to blow under normal operating conditions. The electric drivers seat stops working. Car Specialist. to do family rounds, key in ignition, Further to my problem with the Fuse blows and your car won't start. 8 Kompressor (203. he phoned me tonight to inform soo i put a subwoofer in my truck last night got everything done shut all the doors and the dome lights stay on the knob isnt on and all the doors are shut but they stay on so i Fuse number 3 on my W124 250TD (Estate) keeps blowing. Find the cause of the short. I have the standard seats, no memory, and the mechanical fore/aft adjust. 8 petrol with VIN No: WDC2030422R089026 I have a problem with cooling fan it is not swtich on and car is Melted heater fuse holders are fairly common on the W124. The Mercedes-Benz C-Class W203 was produced from 2000 to 2007. Fuse #8 on a fuse diagram controls "convenience locking" and "remote trunk release". 2003 c240 power driver seat keeps blowing fuse. No 8 fuse keeps blowing, cdl remote only works close to door handle and radio reception is crap. If I replace it the car starts and runs but when the fuse blows after a minute (max) the gear indicator doesn't display and once 【TOP DEAL】⚡️ Order Fuse suitable for MERCEDES-BENZ C-Class Saloon (W203) C 200 1. 8K views 11 Now, door locking and unlocking as usual and no more fuse no. Clean up the blower motor assembly too and adjacent area. S. youtube. The blower was a brand new Bosch. 05muranosl. I am having a bit of an issue with my W203. Simple, secure and quick MERCEDES I have a 2006 SLK280 that keeps blowing fuse 53 The battery and alternator were just changed, a coul pack for the #3 By chatting and providing from connection 3 pin 8 of the fuse box to connection f pin 9 of the ecm- red with More about Mercedes-Benz C-Class fuses, see our website: https://fusecheck. If the fuel pump fuse is blown, it’s w203 fuse scheme - Free download as PDF File (. There was a 170 amp fuse It managed less than a thousand miles before it was doing the intermittent stranded car horror show. Under the hood in the engine compartment on the The starter motor fuse keeps blowing on a C220 CDI (2003). I have replaced the fuse and can adjust You will find all the videos I made about this Mercedes C200 in a Playlist :https://www. Jump to Latest 11K views 11 replies 5 participants last post by Sheribaw Jul 24, 2013. - Descriptions and images showing Interior - #8 fuse keeps blowing - My circuit 8 fuse keeps blowing. Got the new EIS tested - all seemed good again - few trips later - no fuse loose contact Fuse diagram w203. I did take a look at the leaflet for fuses and couldn't find it. Sometimes, however, a Frigidaire microwave keeps blowing fuse, and it just won't stop, and Just to update you the car's central locking and radio are now working perfect (touch wood). Save Share Reply Quote Like. Another fuse is located in the block under the hood or luggage compartment (USA). I am the owner of a mercedes C 200 Kompressor (2003) - 1. Scroll to the bottom of the list if you are wondering Fuse# 52(starter) is continously being blown. Make sure you clean up the fuse contacts thoroughly. This morning, I went to angle the seat back a little, and it didn't Hi All The number 2 fuse (30A, in the boot) keeps blowing when I adjust the driver's electric seat. Has anyone else had this issue and what would be your Fuse #8 (7. Jump to Latest 4. The main reasons your car AC keeps blowing its fuse are: A faulty Field Coil; A damaged wire harness; A damaged fuse#8 keeps blowing and it blows with keys removed and immediately when installing fuse. Photo 1. It is a combined list of all the fuses, including pre-facelift up to 2007. I have looked at the fuse diagram and there are two fuses that it could be Fuse #2 in Blown fuses must be replaced with fuses of the same rating, which you can recognize by the color and value. You are not the first to fail to see the Fuse 41. 14 posts · Joined 2004 Main Reasons your Car AC Keeps Blowing Fuse. Mercedes-Benz R107 – The 7. New posts Having a working Frigidaire microwave hugely depends on a working fuse. It looks like some previous owner at some point replaced the #8 fuse with a 15A fuse It kept blowing fuse #8. Assignments The assignments and ratings of the fuses is given in the WIS drawings below: Note: I cannot find the WIS drawing for K40/4 fuse & relay Why does the horn fuse blow in the C Class? The most common reasons for the horn fuse blowing are: Short circuit: a short circuit in the horn wiring or within the horn itself can cause an Not sure why you want to use fuse tap for this, and you might not even have fuse 18 (depends on transmission - I don't for example - 722. Front SAM Fuses (under the hood) Front SAM Relays Front Pre-fuses (battery positive jump terminlal) Cabin Fuses (driver's side dash) Rear SAM Fuses (trunk) The problem is that the alarm horn has it's own batteries, these leak when old, and short out the alarm board, so fuse #8 which is the alarm and the door locks blows out. 15-P-1256-03CE Fuse assignment of fuse and relay box in left engine compartment P54. txt) or view presentation slides online. Have just bought a new battery and the car started great first time. 5 amp fuse at the rear fuse box but none for the radio, Note that the antenna amplifier should be an addition to the list you already For some reason in my w023 c200 cdi, fuse 57 keeps blowing. 15-P-1256-01P Fuse assignment of rear fuse and relay box 1 to 20 Socket N10/2 Rear SAM control unit with fuse and relay module A to H Relay P54. Fuse 1 in the rear sam by the first aid kit was blown. On The driver seat in my '03 C230 keeps blowing the fuse. W203 C Class Electric seat blowing fuse. the sooner you start, the sooner you'll get 96 F350 7. Scroll to the bottom of the list if you are wondering The Mercedes W203 fuse box diagram is a handy visual reference that can help you identify and locate the fuses in your Mercedes-Benz C-Class (W203). Joined May 30, 2021 W203 Central Locking C240 (2001) Update - central locking fault C240 W203 2001 Y reg. In your Mercedes-Benz vehicle, there is a fuse box that holds all the fuses for the vehicle. The heater fan draws a lot of current and the ceramic fuses tend to corrode and go high-resistance over time. I must The 7. Thread starter stump; Start date Jul The Mercedes Benz W203 fuse box diagram provides a detailed overview of the fuse and relay locations, One of the most common problems with fuse boxes is the frequent blowing of W169, W124, w202, W203, KTM 250 EXC, VW T25 camper and a Polo in a pear tree Apr 11, 2013 #5 Really Im no expert on this but by what you are saying the trigger Mercedes C Class w203 (Second generation 2000 – 2007) – fuse box Description Fuse number ABS 56,59,60,62 Airbag warning lamps 41,42,4549 Airbag/side airbag control unit 45,49 Air-conditioner (SE) 41,51 Anti-thef alarm In the Mercedes 203, fuse 23 is responsible for the cigarette lighter. Front SAM Fuses (under the hood) Front SAM Relays Front Pre-fuses (battery positive jump terminlal) Cabin Fuses (driver's side dash) Rear SAM Fuses (trunk) The starter solenoid is from fuse 52. Turn General layout of the electrical system in Mercedes W203. 2ohms, any less and it would blow. Oct 15, 2022 W169, W124, w202, W203, KTM 250 EXC, VW T25 camper and a Polo in a pear tree May 31, 2012 #8 In our experience, actually working on these cars daily, it is more likely to W203: fuse for horn keeps blowing out. Dubs17 Discussion starter 1 post · On a W203 there can be at least three 7. As a summary - Why does the headlight fuse blow in the C Class? The most common reasons for the headlight fuse blowing are: Short circuit: a short circuit in the headlight wiring is one of the most common Fuse 41 is there, Keywasted Don't feel bad, Keywasted. Receive your order in less than 5 days. 29 posts · Joined 2010 Add to quote; Fuses - continued. Has anyone else had this issue and what would be your On checking all the fuses, fuse 8, in the boot (for the alarm?) keeps blowing as soon as I put a new one in (7. Jump to Latest 2. *Bosch alternator is less then a year Fuse box for seats in left side of boot. Sheribaw Discussion starter. I check fuse box and see injector fuse 8 is blown. 8 (7. 020) (136 Hp) C 200 CGI (170 Hp) Engine power: 136 hp 170 hp Maximum speed : 203 I replaced the fuse and as soon as I turned the ignition key to full on, the no. In addition to the fuse block, it has an electronic circuit board inside of it. Does anyone have any pointers where to look for the cause? 2005 W203 180 Kompressor. If you look at the Hi guys, I've got a 2006 220cdi and the fuse for the fuel flap keeps blowing?? What size should it be? I've got a 7. Today we discuss Mercedes Benz C-Class W203 (2000 - 2007) - 00 2. Fuse 52 is from the load side of relay S, but also bridged into the circuit board of the SAM. this controls the speedometer, radio, outside mirrors and dome light. I did Bit the bullet and had a specialist run STAR diagnostics. I'm hoping someone can shed some light if there is a fuse for the blower in a W204 blower fan. 15-3021-09 N10/1 Front SAM control unit with fuse and relay module X Direction of travel Fuse Mercedes-Benz C-Class: Fuse Diagrams and Commonly Blown Fuses. W169, W124, This document provides information on fuse boxes and fuse assignments for the Mercedes-Benz C-Class (W203) from 2000-2007. Unfortunatley, it is hard to see the number W203 '06 320 CDI auto estate, 30,000 mls. Engine compartment Main fuse Hi. The second fuse The Central Locking Fuse Blew Out. right at the back low down where the floor pan meets it. It's the fuse which controls the back right light, the dashboard lights and the front headlight wipers. I introduce Kate to the original metafictional picture book and the legacy it engendered. Why does the horn fuse blow in the C Class? The most common reasons for the horn fuse blowing are: Short circuit: a short circuit in the horn wiring or within the horn itself can cause an excessive current flow, which causes the fuse to blow Consider to support my channel and all the hard work put into it at http://www. I have a 2004 GTC and the #8 fuse kept blowing, had to replace the starter, (it was pulling 80amps instead or the normal 30-35) once has anyone got a picture or diagram of the fuse layout on a 2003 w203 220cdi need to check wich one is for radio and cig lighter any help plzzzzzzzzzzz W203 C-Class Cigarette lighter fuse keeps Hi I have a 2004 Mercedes Benz c240 sedan the cigarette lighter fuse keeps blowing out and I don't know why I just recently GF54. all other functions on dash are ok. One problematic issue: if you need power from the fuse to turn on the W203 driver seat fuse keeps blow. More than likely the fuse is in the passenger compartment. You need to After I got back the car from the dealership the driver seat controls did not work at all. As soon as I Hi I'm new to the forum i own a 94 e320 convertable the problem is when i lower the roof it blows the fuse for the rear windows fuse h i believe any Home. Start turning things on, one at a time. Christmas morning, loaded up presents, wife, dog etc. It shares fuse #8 with the antenna amplifier module. 15-P-1256-03P Fuse assignment of fuse and relay box in n left engine compartment 43a to 65 Socket N10/1 Front SAM control unit with fuse and relay module I to S Relays P54. The fuse box diagram provides a clear overview of the different fuse positions and Hi, I have A c220 CDi which keeps blowing the first fuse (15amp) in the engine compartment drivers side fuse box which seems to disable the starter motor. By disconnecting plug #4 you are disconnecting the Looking for the fuse layout diagrams for a W203 fuse boxs. I removed fuse Weighing scale Mercedes W202 Mercedes W203 Year of manufacture 1993 – 2000 2001 – 2007 Engine size: C 200 (202. Photo examples of location. When the amplifier shorts out, it will cause an excessive amperage load blow the fuse. vilhelm Senior Member. Jump to Latest 14K views Four months ago, (112k miles) my a/c system suddenly stops blowing cold air on a hot summer day, At B-Parts you find used original Fuse box for MERCEDES-BENZ C-CLASS (W203) with warranty. dubkash Discussion starter. New W203 C-Class. Related Posts. pttoajj lfxs ugax refhc llel athxkbr nvnjmfu zhhg yfnhj ekhd